This circuit shows how to use a
solid state relay to drive high current loads with the LCRX. The Crydom
D2W230F is driven off the voltage drop developed across the cab lamp.
Contact terminals 1 and 2 can be used to drive an AC load up to 3 amps.
This circuit takes advantage of the DC offset present at the outputs in
command mode.
AUX-2 will turn on the cab lamp and allow you to control the relay with
the AUX-1, 8, 9, and 0 buttons. Playing with these functions will give you
different combinations of outputs.
|
|